Skip to Content

Renode Backend

Relevant source files

The Renode backend serves board virt-pi5. In the spec it is the primary build: Pi 5 drivers, sensors, and deterministic execution. On main it implements a bounded boot check driven by virtual time.

Adapters

ScriptBehavior
doctor.shRequires renode, timeout, realpath, sha256sum; prints renode --version
test.shExports VOLN_VP_BOOT_MARKER='=== axiomos eBPF init ===' (tests always prove userspace entry), then exec run.sh
run.shValidates inputs, stages a run directory, runs Renode under timeout, checks UART and Renode log

run.sh flow

Renode invocation

renode --config RUN_DIR/renode.config --disable-gui --plain -P 0 [extra args] RUN_DIR/boot.resc \ -e "sysbus.uart0 CreateFileBackend \"RUN_DIR/uart.log\" true; emulation RunFor \"VIRTUAL_TIME\"; quit"

The generated boot.resc sets $axiomos_kernel and $virt_pi5_dtb to the staged symlinks and then includes backends/renode/scripts/boot-virt-pi5.resc. Renode runs from the repository root. The UART file backend flushes immediately. The guest runs for exactly VOLN_VP_VIRTUAL_TIME virtual seconds (default 0.1), bounded independently by the VOLN_VP_TIMEOUT wall clock (timeout --kill-after=2s).

Monitor path quoting

Renode parses paths at two levels. The positional script path is re-parsed as Monitor syntax, so spaces are backslash-escaped; paths inside the script are quoted strings. The artifact directory must match ^[[:alnum:]_./ -]+$, otherwise the adapter exits 4. Input images are staged as symlinks so their real paths never enter Monitor syntax. See the Renode Monitor syntax documentation .

Pass and fail rules

Renode 1.16 can exit zero after Monitor errors, and a bounded run can finish without guest progress, so process status alone never passes.

CheckPatternResult
UART panickernel panicked, V04_PANIC, PANIC:, panicked at, BOOT_FATAL (case-insensitive)FAIL 1
Renode log error[ERROR], [FATAL], There was an error, Error while, Unhandled exception, Could not execute, Could not tokenize, No such commandFAIL 1
Markerfixed-string VOLN_VP_BOOT_MARKER in uart.logPASS 0
Renode nonzerotimeout gives 124FAIL with that status

On failure the last 80 lines of uart.log and renode.log are printed.

Exit codes

CodeCause
2Boot script missing, kernel not a readable file, DTB not found
3renode, timeout, realpath, or sha256sum missing
4Invalid timeout, virtual time, or artifact-directory characters
124Wall-clock timeout
130 / 143Interrupted by SIGINT / SIGTERM (Renode process group stopped)

Process cleanup

Renode can spawn dotnet. The adapter runs it in a subshell under timeout, records the PID, and on exit or signal sends SIGTERM then SIGKILL to the whole process group before waiting.

Run directory

voln-vp-renode.XXXXXX/ contains uart.log, renode.log, version.log, inputs.sha256 (kernel, DTB, boot script, .repl), command.txt (cwd, timeout, marker, quoted command), boot.resc, and symlinks kernel.elf and virt-pi5.dtb.

Tests

  • test_mailbox.py exercises mailbox.py behavior.
  • test_platform_contract.py asserts EL1 entry precedes image load and that no high-address alias exists.

On the unmerged branch stack, run.sh is extended with manifest staging (private copies instead of symlinks), atomic result.json, --mode runtime via renode-test and Robot suites, a VOLN_VP_STRICT_MMIO warning gate, and C# RP1 unit models. See Runtime Scenarios and RP1 Models.